Building stairs follows strict rules based on years of carpentry experience and human ergonomics. Here is a quick overview of the most important terms you should know before cutting:
US Stair Code Limits (IRC 2021)
For homes in the US the IRC allows a riser of 7 3/4″ maximum and a tread run of 10″ minimum. Risers in one flight may differ by no more than 3/8″. Where the tread is shallower than 11″, solid risers need a 3/4″ to 1 1/4″ nosing.
How Many Steps Do I Need?
Divide the total rise (finished floor to finished floor) by 7 3/4″ and round up – that is the smallest number of risers the IRC allows. The upper floor is usually the last step, so there is one tread fewer than risers. Example: 105″ ÷ 7 3/4″ = 13.5 → 14 risers of 7 1/2″ and 13 treads.
Headroom, Width and Handrails (IRC)
Keep at least 6′8″ of headroom above the nosing line and a stair width of 36″. A flight with four or more risers needs a handrail 34–38″ above the nosings. Open sides higher than 30″ need a guard, and openings must not pass a 4″ sphere.
Ideal Step (Blondel's Rule)
The basic rule for comfortable stairs is: 2 × riser height + stringer going = approximately 630 mm (about 25″), or about 600–650 mm (24–25 1/2″). The calculator uses Blondel’s rule to calculate the ergonomic layout.
Riser Height
For comfortable interior stairs, a height of 170–180 mm (approx. 7") is recommended. Above 200 mm, stairs become very steep and less safe.
Tread Depth
The net horizontal area for the foot. The practical ideal range is 270–300 mm (approx. 10.6–11.8") to safely accommodate a whole foot.
Two Tread Design Modes
Automatic mode designs the depth from the rise, ergonomics, and available space. Fixed Depth mode preserves the physical tread board size you already have or need to use.
Tread Board vs. Stringer Going
The overall physical board depth includes the nosing. The actual horizontal stringer going therefore equals the overall board depth minus the nosing.
Available Stair Run
In Fixed Depth mode, the calculator checks whether all steps fit within the entered space. If they do not, it keeps your board depth unchanged and shows the actual required run.
Stringer Throat
The narrowest part left after cutting notches. Carpenters recommend keeping at least 115–120 mm (4.5") of solid wood for standard loads.
First Step Cut (Dropping)
The bottom cut of the stringer must be shortened by exactly the tread thickness. Otherwise, the first step would be higher than the rest.
Tread Nosing
Increases the total stepping area. Usually 20–30 mm. Helps significantly when walking down by providing more heel space.
Sawn vs. Housed Stringers
Calculator dimensions are universal. Use them for cutting teeth on sawn stringers or as precise guides for routing housed stringer grooves.
Headroom
Don't forget your head! The vertical distance between the step edge and the ceiling above should be at least 2100 mm (83").
Top Mounting
Stringers can end "dropped" (floor above acts as the top step) or "flush" (stringer is level with the floor and a tread is mounted on top).
U-shaped stairs
Two flights side by side with a landing between them where you turn 180°. They need a shorter run than a straight flight but are roughly twice as wide. The calculator works out both flights, the landing and the joint with the landing beam.
Landing depth
In the direction of travel the landing should be at least as deep as the flight is wide – check the exact limit in your local code. Leave the field empty and the calculator sets it for you: flight width + nosing + riser.
Equal risers in both flights
The landing counts as one of the steps, so the riser height must be the same in the lower and upper flight. The landing height is always a whole multiple of the riser. Even a few millimetres of difference can be felt when walking.
Splitting the risers
By default the risers are split roughly in half. You can set the number in the lower flight yourself, for example to place the landing under a window or at a door. Fewer risers below make the upper flight longer, so it may reach further back.
Landing beam and stringer joint
Both stringers bear on the landing beam – either on a screwed-on ledger or in a groove in the beam. The joint drawing shows the dimension from the top of the beam to the ledger. The suggested beam size is indicative, not a structural calculation.
Footprint, gap and ceiling opening
The overall width is 2 × flight width + the gap between the flights. The upper flight can reach beyond the start of the lower one – the overall dimension shows it. The ceiling opening must be above the upper flight and the landing.
⚠️ Disclaimer: This calculator is a geometric tool for carpenters and DIYers. It does NOT perform structural engineering. Always consult a professional engineer regarding load-bearing capacity.